electromagnetic
Keyword:
Category:
Product Details
Features
The electromagnetic flowmeter produced by our company is a high-precision, high-reliability product that integrates the advantages and disadvantages of flowmeters from all over the world. The flowmeter has reached the world's advanced level in excitation technology, lining technology, and intelligent technology. It is suitable for measuring the volume flow of conductive media such as acid, alkali, salt solution, mud slurry, pulp, and wastewater. It has the following characteristics.
◆ The measurement is not affected by changes in fluid density, viscosity, temperature, and pressure
◆ There is no flow block in the measuring pipe, the pressure loss is small, and the maintenance-free straight pipe section requires low requirements
◆ The sensor can be equipped with a grounding electrode to achieve good grounding of the instrument
◆ The sensor adopts advanced processing technology and has good negative pressure resistance
◆ Full digital processing, strong anti-interference ability, reliable measurement, and high accuracy
◆ It has two-way flow measurement and two-way total accumulation functions
◆ HART communication function
Technical Parameters
|
Model |
TST-TE |
|
Accuracy |
±0.5% of measured value (standard), ±0.2% of measured value (high accuracy) |
|
Repeatability |
0.2% of measured value |
|
Nominal diameter (mm) |
DN6~DN1600 |
|
Pressure level |
0.6MPa~4.0MPa, Special: According to user requirements |
|
Conductivity |
>5μS/cm |
|
Lining material |
Soft/hard rubber, PTFE, PFA |
|
Electrode material |
316, 316L, Hb, Hc, titanium, tantalum, platinum-iridium, etc. |
|
Flange material |
Carbon steel, stainless steel |
|
Grounding electrode (ring) material |
316, 316L, Hb, Hc, titanium, tantalum, platinum-iridium, etc. |
|
Connection |
Flange connection |
|
Converter connection type |
Integrated, Split |
|
Protection level |
IP65, IP68 (Optional) |
|
Medium temperature |
-50~+130℃ |
|
Explosion-proof design |
Exd[ia]iaqⅡCT5 |
|
Power supply |
24VDC or 220VAC |
|
Signal output |
Current 4-20mA, frequency output, pulse output |
|
Forward/reverse direction measurement |
Have |
|
Electrical interface |
M20×1.5 or 1/2〃NPT |
|
Communication |
HART communication, RS485 communication |
|
Environmental conditions |
Ambient temperature: -20℃~+60℃; relative humidity: 5%~90% |
|
Shell |
Cast Aluminum |
Installation Requirements

Installation on large diameter pipes

Exhibition Display
Customer Message
Plant Display
Q&A
Sample available if we have products in stock, but the customers have to pay the sample cost and the courier cost. We can reduce sample cost from further order according to your quantity.
T/T (50% as deposit, and 50% before shipping), Aliba ba Trade assurance (same safe as Paypal).Pictures of the products and packages will be showed to you before shipping.
Generally, it will take 30 to 50 days after receiving payment. The specific delivery time depends on the items and the quantity of your order.
ODM & OEM service accepted, including selections on size, materials, design, packing method, etc., according to your requirements. Logo and brand customization also are available.
Related products
Product Message
Tuosite
Follow us
Copyright © 2023 Taian tuoster instrument co., LTD